Chlorine Reagent Tablets CL203
Chlorine Reagent Tablets CL203
เม็ดน้ำยาสำหรับวัดค่า คลอรีน
Features:
- Includes 10 packs (10 tablets ea.)
- Requires 1 tablet per test - enough for 100 tests
- Foil packaging provides very stable environment with long shelf life
- No messy powder reagents
- No dosing equipment required
HI95771C Chlorine Meter
Chlorine Ultra High Range ISM
เครื่องวัดคลอรีน HI95771C
Specifications:
Range: 0 to 500 mg/L
Resolution: 1 mg/L (10 mg/L above 200 mg/L)
Accuracy: ±2 mg/L to 100 mg/L
Light Source: Tungsten lamp with narrow band interface filter 525 nm
Light Detection: Silicon Photocell
Power Supply: 1 x 9V battery
Auto Shut-off: After 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode
Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
Weight: 290 g (10 oz.)
Method: Standard Methods 4500-Cl Adaptation of USEPA 330.5 method
Free Chlorine Test HI3831F
ชุดทดสอบคลอรีน อิสระ
Free Chlorine Test HI3831F Chlorine - Range (0.0-2.5 mg/L)
Chlorine is the most commonly used water disinfectant in applications that vary from treatment of drinking water and wastewater, pools and spas sanitization, to food processing and sterilization. Chlorine present in water binds with bacteria, leaving only part of the original quantity (free chlorine) to continue its disinfecting action. If the free chlorine level is improper with respect to the pH, water will have an unpleasant taste and odor and the disinfecting potential of the chlorine will be diminished.
Free chlorine reacts with ammonium ions and organic compounds to form chlorine compounds with diminished disinfecting capabilities compared with free chlorine. Combined chlorine and free chlorine together result in total chlorine content.
HI711เครื่องวัดคลอรีน
Checker Total Chlorine HI711
เครื่องวัดคลอรีน HI711
Easier to use and more accurate than chemical test kits EPA approved DPD method ±0.03 ppm ±3% of reading accuracy 0.01 ppm resolution, 350 points Large, easy to read digits Auto shut off
เครื่องวัดค่าคลอรีน HI95734C
HANNA HI96734C Portable Free & Total Chlorine Photometer
เครื่องวัดคลอรีน HI96734C
Range Free Cl2 0.00 to 10.00 mg/L
Total Cl2 0.00 to 10.00 mg/L
SPECIFICATIONS:
- Range: Free Cl2 0.00 to 10.00 mg/L
- Total: Cl2 0.00 to 10.00 mg/L
- Resolution: 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
- Precision: ±0.06 mg/L @ 3.00 mg/L
- Light Source: Tungsten lamp with narrow band interference filter @ 525 nm
- Light Detector: Silicon Photocell
- Method: Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the DPD reagent causes a pink tint in the sample.
- Environment: 0 to 50°C (32 to 122°F); max 95% RH non-condensing
- Battery Type: 1 x 9 volt
- Auto-Shut off: After 10' of non-use in measurement mode; after 1 hour of non-use in calibration mode.
- Dimensions: 180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
- Weight: 290 g (10 oz.).
Turbidity and Free/Total Cl2 Portable Meter HI93414
Turbidity and Free/Total Cl2 Portable Meter HI93414
with CAL CHECK™ and Fast Tracker™, EPA Compliant
-
High accuracy at low ranges
-
Exclusive chlorine CAL CHECK™ calibration validation
-
Exclusive Fast Tracker™ system
-
User replaceable light source
-
Two, three or four point turbidity calibration
-
USB and RS232 PC connectivity
-
GLP features
-
Logging for up to 200 readings
-
User friendly, backlit display with guidance codes
-
Auto-off
-
Battery % on startup
-
Continuous current time on display
The HI 93414 measures the most important parameters of drinking water: turbidity and free/total chlorine. Designed for water quality measurements, HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.